The 6 Numbers Your Sleeving Supplier Needs: How to Specify Heat-Treated Fibreglass Sleeving
"Need 6 mm high-temperature sleeve, please quote" leaves a supplier guessing. Six numbers turn that into a precise specification, and collecting them usually takes less than an hour.
Most enquiries for high-temperature sleeving arrive as one line: "Need fibreglass sleeve, 6 mm, high temperature, please quote." A supplier can quote that, but not well. Which 6 mm? How high a temperature? Over what? How much, and how often?
Each missing detail is a guess, and guesses lead either to a sleeve that is more expensive than it needs to be, or to one that fails in service. This article sets out the six numbers that turn a vague enquiry into a precise quotation for heat-treated fibreglass sleeving. It is written for buyers, design engineers and heater manufacturers. Collecting the six numbers usually takes less than an hour.
Number 1: continuous temperature at the sleeve
This is the number that decides the material, and it is the one most often given wrongly. Enquiries usually quote the heater's set point or the element temperature. What matters is the temperature at the sleeve itself, at its hottest point, during normal operation.
Those can be very different. The element inside a cartridge heater may be several hundred degrees hotter than the lead exit. A band heater's terminal area can be much hotter than the lead 200 mm away. Quoting the element temperature can push you into a more expensive solution than you need; quoting the room temperature can leave you with a sleeve that fails.
How to measure it
- Thermocouple on the lead. Fix a fine thermocouple to the lead surface at the hottest point, usually where it leaves the heater, and run the equipment at its worst-case duty until the reading stabilises.
- Temperature-indicating labels. Irreversible labels change colour when a set temperature is reached. They are inexpensive, need no instrument and are useful on equipment already in the field.
- Check worst case. Highest set point, highest ambient, enclosure closed, fan off if it can fail.
What the number decides
| Continuous temperature at the sleeve | Typical choice |
|---|---|
| Up to about 125–150 °C | A polymer sleeve such as PET may be enough, and costs less |
| Up to about 150–180 °C, with cut or abrasion risk | Aramid, SYN-KEV |
| Above about 150 °C, no smoke allowed on start-up | Heat-treated glass, SYN-HT-FBG |
| Above about 150 °C, initial smoke acceptable | Standard glass, SYN-FBG |
| Above 350 °C | Discuss with us before ordering |
The 350 °C line is the rating that IEC 60684-3-300 gives uncoated E-glass sleeving. Above it, glass strength begins to fall significantly over time, so the application needs closer review. The reason heat-treated glass is chosen when smoke matters is explained in why new heaters smoke.
Number 2: peak temperature and how long it lasts
Many applications have a normal temperature and occasional excursions: start-up overshoot, a controller fault, a fan failure, a mould left heating with no production. A good enquiry gives both the peak and its duration, for example "320 °C for up to 10 minutes at start-up".
Why it matters: a short excursion that a glass sleeve tolerates easily might still rule out aramid or PET. And a long, repeated excursion above 350 °C may be the real design case, even if normal running is far below it.
Number 3: bundle size, as an equivalent diameter
"6 mm sleeve" can mean three different things: the nominal size code, the relaxed diameter, or the bundle diameter. Synflex size 006, for example, covers bundles from 3 to 9 mm. The useful number is the bundle's equivalent round diameter, and ideally its range if the bundle varies between products.
- One round lead: its outside diameter.
- Several equal leads: lead diameter × 1.64 for two, × 1.95 for three, × 2.27 for four, × 2.91 for six or seven.
- Anything else: wrap a thread once around the bundle, measure it, divide by π.
Give a minimum and maximum if you have a product family. A supplier can then suggest one size that covers several products, which simplifies stock. The full method is in our heater lead sizing guide.
Number 4: the largest fitting the sleeve must pass over
If the sleeve is fitted after the leads are terminated, it must pass over the largest ring terminal, ferrule, plug or connector on the way. That fitting, not the lead bundle, can set the minimum size.
Give the largest dimension across the fitting, and say whether the sleeve goes on before or after termination. If it goes on before, write "N/A". It is one of the easiest numbers to collect and one of the most common reasons a correctly sized sleeve fails on the assembly line.
Number 5: cut length and tolerance, or spool supply
Do you want sleeving on spools to cut yourself, or cut to length? If cut, give:
- The length and tolerance, for example 300 mm ± 5 mm. A braid relaxes slightly after cutting, so very tight tolerances should be discussed.
- How the ends should be finished, if at all. Glass cannot be heat-sealed like PET; ends can be left cut, taped, or varnish-locked during your own process.
If you cut your own, the spool length matters for your line. Synflex spools run from 1,000 m on the smallest size down to 100 m on the largest.
Number 6: quantity, per order and per year
Two quantities, not one:
- Per order, in metres (or pieces for cut lengths). Synflex's minimum order is 500 m per size.
- Per year, which lets a supplier plan stock, offer better pricing, and keep your size available. Standard sizes ship from stock or short lead time; custom constructions take one to two months, so annual volume matters most for those.
Converting pieces to metres is simple, but remember the waste allowance: 40,000 pieces a year at 300 mm is 12,000 m before any allowance for setup and offcuts.
A worked example
A cartridge heater manufacturer sends this enquiry:
| Number | Customer's answer |
|---|---|
| 1. Continuous temperature at the sleeve | 280 °C at the lead exit (measured with a thermocouple) |
| 2. Peak and duration | 320 °C for up to 10 minutes at start-up |
| 3. Bundle size | 2 leads × 2.0 mm OD, so 3.3 mm equivalent |
| 4. Largest fitting | Sleeve fitted after crimping; ferrule 4.5 mm across |
| 5. Cut length | 300 mm ± 5 mm, ends cut clean |
| 6. Quantity | 10,000 pieces per order; 40,000 per year |
The answer follows directly:
- 280 °C continuous and a heater customer who will see smoke on first switch-on: heat-treated glass.
- Peak 320 °C, under the 350 °C line: no special review needed.
- Bundle 3.3 mm sits in the lower half of size 006 (3–9 mm). The 4.5 mm ferrule plus a 15 % margin is 5.2 mm, comfortably inside the range.
- Result: SYN-HTFS-006, about 3,000 m per order plus waste allowance, 12,000 m or more per year.
Compare that with "6 mm high temperature sleeve". The six numbers took the customer perhaps 45 minutes to collect, and turned a guess into a specification.
Beyond the six numbers: what else helps
The six numbers define the sleeve. A few non-numerical details help a supplier get the rest right:
- Environment: oil, water, chemicals, vibration, sunlight. Open braid wicks liquids, which affects the advice.
- Standards or customer specifications the finished product must meet.
- Documentation you need with deliveries, such as a certificate of conformity or material declarations.
- A photo or drawing of the application. One picture often answers questions nobody thought to ask.
Copy this into your next enquiry
| # | Item | Your answer |
|---|---|---|
| 1 | Continuous temperature at the sleeve (°C), and how measured | |
| 2 | Peak temperature (°C) and duration | |
| 3 | Bundle equivalent diameter, min and max (mm) | |
| 4 | Largest fitting to pass over (mm), or N/A | |
| 5 | Spool, or cut length and tolerance (mm) | |
| 6 | Quantity per order and per year (m or pieces) | |
| + | Environment, standards, documentation, photo |
Frequently asked questions
What information do I need to quote high-temperature sleeving?
Six numbers: continuous temperature at the sleeve, peak temperature and duration, bundle equivalent diameter, the largest fitting the sleeve passes over, cut length or spool supply, and quantity per order and per year.
Should I give the heater temperature or the sleeve temperature?
The sleeve temperature, measured at its hottest point during worst-case operation. The heater element or set point can be very different from what the sleeve actually sees.
What does "6 mm sleeving" mean?
It is ambiguous. It may be a size code, a relaxed diameter or a bundle diameter. Synflex size 006, for example, fits bundles from 3 to 9 mm. Always give the bundle's equivalent diameter instead.
What is the minimum order for Synflex heat-treated sleeving?
500 metres per size. Standard sizes are available at short lead times; custom constructions take one to two months.
The bottom line
A good sleeving enquiry fits on one line of a table: six numbers and a short note. Measure the temperature at the sleeve, not the heater. Give the bundle as an equivalent diameter, not a vague "6 mm". Remember the fitting it must pass over, and give annual volume as well as order size. Do that, and you will get a sleeve that fits, survives, and costs no more than it should.
References
- IEC 60684-3-300, Flexible insulating sleeving: Textile glass sleeving.
- Synflex Industries LLP catalogue data for SYN-HT-FBG, SYN-FBG and SYN-KEV expansion ranges and spool lengths.
Where this shows up in the catalogue
Have a specification question?
Send your application details and we'll help match the right product and configuration.
Have your six numbers?
Send them through our enquiry form and we will reply with a size, a construction and a quotation. Or see heat-treated fibreglass sleeving sizes first.